CooLifting Cleaning Kit - A kit to be used to prevent your CooLifting device from getting clogged
When placing a new CooLifting order online (shop.promedsi.com), you can request to add a CooLifting Cleaning Kit to your order free of charge.
Just place a note at checkout and we will include a CooLifting Cleaning Kit with your order.
The CooLifting Cleaning Kit includes a 10ml syringe and an empty serum vial. They are connected by a Luer lock.
Fill the syringe with distilled water, connect the serum vial, and insert the cleaning kit into the CooLifting device.
While keeping the tip of the CooLifting gun over a sink or bowl, SLOWLY press the plunger of the syringe until liquid comes out the tip of the gun. Once the plunger is fully pressed, pull up on the plunger allowing air to fill the syringe. Flush air through the device two to three times ensuring no liquid remains in the device.
***Please note- if the rubber gasket of the serum vial becomes compromised due to continual use please do not continue to use this to clean the device. The rubber will clog the serum lines and you will need to send in your device for service to remove the rubber.
Should you have any questions please contact ProMed Solutions at (562) 326-5720 or e-mail us at support@promedsi.com.
Related Articles
Troubleshooting the Coolifting Device - Coolifting Gun is Clogged - Trigger is Stuck
This article outlines the procedure set by the Coolifting Manufacturer to unclog a Coolifting Gun. This procedure will create negative pressure in the device and force CO2 to flow through the serum puncture needles. While performing a Coolifting ...
Coolifting 2.0 User Manual
Please download the attachment found in this article to view the Coolifting 2.0 User Manual as a PFD. Should you have any questions please contact ProMed Solutions at (562) 326-5720 or e-mail us at support@promedsi.com. As always, thank you for your ...
Coolifting Informed Consent Forms
Attached are two different Informed Consent forms.
Coolifting- How to locate your serial number
This article outlines to procedure to locate your Coolifting device's serial number. Coolifting Gun: 1. Locate the CO2 insertion point. 2. The serial number is printed on a label and is located on the left, inside of the CO2 insertion point on the ...
CooLifting Training and Procedure Videos
These are the Coolifting 1.0 procedure videos, but serve as a great resource for the Coolifting procedure recommended by the manufacturer. For the Coolifting 2.0 procedure, the duration of the procedure has changed to three minutes and the menu ...